Brand Name: | GFUVE |
Model Number: | GF6018A-20 |
Certification: | CE, ISO9001, KEMA |
Place of Origin: | BEIJING CHINA |
MOQ: | 1SET |
Price: | 12000-20000USD/SET |
Payment Terms: | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability: | 200sets/month |
Delivery Time: | 2-3weeks |
Packaging Details: | Standard Export Wooden Box |
Name: | Multimeter Calibration Test Equipment |
Application: | lab, multimeter factory |
Class: | 0.05 |
Calibration coil: | 200A, 600A, 1000A |
Weight: | 12kg |
Current range: | 0-24A AC/DC |
Voltage range: | 0-1000A AC/DC |
Resistance: | 0-4M Ω |
Theory: | current & voltage power amplifier |
Communication: | RS232 |
The equipment of clamp type multi product multimeter calibrator is
compliance with national verification regulation: JJG124-2005
“Ammeter, voltmeter, power meter and resistance meter verification
rules” and related national standards. 0.05 single-phase AC/DC
standard source, can verify magnitude 0.2 and the following AC/DC
voltmeter, ammeter, frequency meter, resistance meter. The source
signals by using DSP and 16-bit high-speed analog-to-digital
converters of controllable sine wave, the distorted wave signal
source.The equipment comes with RS-232 interface, can be connected
with PC to a semi-automatic verification system. It has precise
interface and multi-functions including verification, storage and
query.The equipment adopts color LCD screen, chart character
display is clear, with high precision, stable and reliable,
convenient operation and flexible characteristics.
Theory
Calibration of multimeter in measurement technology and metrology
is the comparison of measurement values delivered by a device under
test with those of a calibration standard of known accuracy. Such a
standard could be another measurement device of known accuracy, a
device generating the quantity to be measured such as a voltage, or
a physical artefact, such as a metre ruler.
The outcome of the comparison can result in no significant error
being noted on the device under test, a significant error being
noted but no adjustment made, or an adjustment made to correct the
error to an acceptable level. Strictly speaking, the term
calibration means just the act of comparison, and does not include
any subsequent adjustment.
The calibration standard of multimeter and clamp meter is normally
traceable to a national standard held by a National Metrological
Institute.
Electrical parameters | ||
---|---|---|
Power supply | Single phase AC 220V±10% or 110V±10%, 50/60HzAC | |
AC Voltage output | ||
range | 200mV, 400mV, 2000mV, 4000mV, 20V, 100V, 200V, 500V, 1000V | |
Range 20V-1000V | Accuracy | ±(0.03%RD+0.02%FS) |
Stability | ≤0.01% FS /60s | |
Range 200mV-4000mV | Accuracy | ±(0.3%RD+0.2%FS) |
Stability | ≤0.04% FS /60s | |
Load capacity | 20VA | |
Waveform distortion | ≤0.3% | |
Adjustable Range | 0-120% FS (1000V not included) | |
Fineness | 5×10-5 | |
AC Current Output | ||
Range | 2mA, 4mA, 20mA, 40mA, 0.2A, 0.5A, 2A, 5A, 10A, 20A | |
Range 0.2A-20A | Accuracy | ±(0.03%RD+0.02%FS) |
Stability | ≤0.01% FS /60s | |
Range 2mA-40mA | Accuracy | ±(0.3%RD+0.2%FS) |
Stability | ≤0.04% FS /60s | |
Load capacity | 20VA | |
Waveform distortion | ≤0.3% | |
Adjustable Range | 0-120% FS | |
Fineness | 5×10-5 | |
Frequency Output | ||
Range | 45-65Hz | |
Fineness | 0.001Hz | |
Accuracy | 0.01Hz | |
Harmonic Wave | ||
Times | 2-31 | |
Extent | 0-20% | |
Each harmonic phase fineness | 0.01·N (N is harmonic order) | |
DC voltage output | ||
Range | 200mV, 400mV, 2000mV, 4000mV, 20V, 40V, 100V, 200V, 400V, 1000V | |
Load capacity | 20W | |
Adjustable range | 0-110% FS (1000V not included) | |
Adjustable fineness | 5×10-5 | |
Stability | ≤0.01% FS /60s (peak-peak value) | |
Accuracy | ±(0.03%RD+0.02%FS) | |
Ripple wave | ≤1% FS | |
DC current output | ||
Range | 20uA, 40uA, 200uA, 400uA, 2mA, 4mA, 20mA, 40mA, 0.2A, 1A, 2.5A, 5A, 10A, 20A | |
Load capacity | 20W | |
Adjustable Range | 0-110% FS (1000V not included) | |
Adjustable Fineness | 5×10-5 | |
Stability | ≤0.01% FS /60s (peak-peak value) | |
Accuracy | ±(0.06%RD+0.04%FS) | |
Ripple wave | ≤1% FS | |
Resistance box | ||
Range | 0-200Ω, 200-400Ω, 0-2kΩ, 2kΩ-4kΩ, 0-20kΩ, 20kΩ-40kΩ, 0-200kΩ, 200kΩ-400kΩ, 0-2MΩ, 2MΩ-4MΩ | |
Fineness | 0.02% | |
Range 0-2kΩ, 0-20kΩ, 0-200kΩ | ||
Range 0-2kΩ | Adjustable Range | 0-100%FS |
Accuracy | ±(0.12%RD+0.08%FS) | |
Range 0-200Ω,0-2MΩ | Adjustable Range | 0-100% FS |
Accuracy | ±(0.3%RD+0.2%FS) | |
Range 2kΩ-4kΩ, 20kΩ-40kΩ, 200kΩ-400kΩ | ||
Range 2kΩ-4kΩ | Adjustable Range | 5%-100%FS |
Accuracy | ±(0.12%RD+0.08%FS) | |
Range 200-400Ω, 2MΩ-4MΩ | Adjustable Range | 5%-100% FS |
Accuracy | ±(0.3%RD+0.2%FS) | |
Clamp meter range | ||
200A | Accuracy | ±0.2% |
600A | Accuracy | ±0.5% |
1000A | Accuracy | ±1% |
Dot frequency square wave output | ||
Range | 1kHz, 5kHz, 10kHz, 50kHz, 100kHz, 200kHz, 1000kHz | |
Square wave amplitude | 4.5V | |
Setting accuracy | 5×10-5 | |
Mechanical parameters | ||
Dimension (L×W×H) (mm) | 440x360x160 | |
Weight (kg) | 12 | |
Environmental conditions | ||
Operating temperature | 20°C±10°C | |
Relative humidity | ≤85%RH |
![]() |