| Sign In | Join Free | My entremaqueros.com | 
 | 
| Categories | Fluid Level Meter | 
|---|---|
| Brand Name: | KACISE | 
| Model Number: | KUS3000-M30 | 
| Certification: | CE | 
| Place of Origin: | CHINA | 
| MOQ: | 1PCS | 
| Price: | Negotiable | 
| Payment Terms: | L/C, T/T, Western Union, MoneyGram | 
| Supply Ability: | 1000 Piece/Pieces per Week negotiable | 
| Delivery Time: | 5-8 work days | 
| Packaging Details: | each unit has individual box and all boxes are packed in standard packages or customers requests available | 
| Range: | 3000mm | 
| Blind zone: | 150mm | 
| Protection grade: | IP65 (IP67 selectable) | 
| Material: | Plastic or Metal | 
| Power Supply: | 10 ... 30 V DC | 
| Output: | 4-20mA / 0-10V | 
| Company Info. | 
| Xi'an Kacise Optronics Co.,Ltd. | 
| Verified Supplier | 
| View Contact Details | 
| Product List | 
3m Range 4-20mA / 0-10V Small Diameter Ultrasonic Sensor For Industrial Automation
Features
Non-contact
Teachable
Measuring window adjustable
Small unusable area
Introduction
Ultrasonic sensor measure is a reliability and outstanding versatility measurement method. It can realize to solve the most complex projects including object detection or level measure, because its measuring way works reliably under almost all conditions.
Appliactions
Level measuring
Mechanical engineering
Material handling
Food industry
Woodworking and furniture
Agriculture
Construction
Paper making
Dimensions

Parameters
General specifications
| M18 | |
| Sensing range | 100... 1000 mm | 
| Adjustment range | 100….1000mm | 
| Unusable area | 0 ... 100 mm | 
| Standard target plate | 100 mm x 100 mm | 
| Transducer frequency | approx.220 kHz | 
| Response delay | approx. 10 ms | 
| M30-type1 | |
| Sensing range | 200... 2000 mm | 
| Adjustment range | 200….2000mm | 
| Unusable area | 0 ... 200 mm | 
| Standard target plate | 100 mm x 100 mm | 
| Transducer frequency | approx.150 kHz | 
| Response delay | approx. 10 ms | 
| M30-type2 | |
| Sensing range | 300... 3500 mm | 
| Adjustment range | 300….3500mm | 
| Unusable area | 0 ... 150 mm | 
| Standard target plate | 100 mm x 100 mm | 
| Transducer frequency | approx.70 kHz | 
| Response delay | approx. 20 ms | 
| M30-type3 | |
| Sensing range | 400... 6500 mm | 
| Adjustment range | 400….6500mm | 
| Unusable area | 0 ... 300 mm | 
| Standard target plate | 100 mm x 100 mm | 
| Transducer frequency | approx.50 kHz | 
| Response delay | approx. 40 ms | 
Indicators/operating means
| LED blue | Power on | 
| LED yellow | solid: object in the evaluation range | 
| flashing: program function, object detected | |
| LED red | solid: Error | 
| flashing: program function, no object detected | 
Electrical specifications
| Operating voltage UB | 10 ... 30 V DC , ripple 10 %SS | 
| No-load supply current I0 | ≤ 50 mA | 
Output
| Output type | 1 analog output 0-10V or 4…20mA. | 
| Resolution | Evaluation range [mm]/4000, but ≥0.35mm | 
| Deviation of the characteristic curve | ≤0.2% from full-scale value | 
| Repeat accuracy | ± 0.1 % of full-scale value | 
| Load impedance | >1k Ohm | 
| Temperature influence | ≤ 2 % of full-scale value | 
Ambient conditions
| Ambient temperature | -25 ... 70 °C | 
| Storage temperature | -40 ... 85 °C | 
Mechanical specifications
| Connection type | Device connector M12 x 1 , 4-pin | 
| Protection grade | IP65 (IP67 selectable) | 
| Material | Housing: nickel plated brass or plastic | 
LED Displays
| Displays in dependence on operating mode | Red LED | Yellow LED | 
| TEACH-IN evaluation limit Object detected No object detected Object uncertain (TEACH-IN invalid) | off flashes on | flashes off off | 
| Normal mode (evaluation range) | off | on | 
| Fault | on | previous state | 
Installation conditions
If the sensor is installed at the environment temperature fall below 0℃,It should do well on the protective measures. In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing thread.
Sensor Function Description
Set and adjust the switching point and advance interval of the
switching output and analog output products
Switching and analog output can be set using the tuning end,
specifically, there are eight working modes that can be set.
Each of these Settings is divided into the following steps:
In the first step, the user selects a self-set distance or puts the
sensor into the wave-loss state.
Second, connect the calibration terminal to the power supply or
GND, and keep the connection until the yellow light blinks (or the
red light blinks if the state is lost).
In the third step, the user selects the second self-set distance or
allows the sensor to enter the wave loss state.
In the fourth step, connect the calibration terminal to the GND or
power supply (different state from the second step), and keep the
connection until the yellow light blinks (or the red light blinks
in the case of wave loss).
There are 8 modes of switching output
1. Window normally open mode (analog output products for positive linear working mode or distance measurement mode).
2. Window normally closed mode (analog output product is negative linear operation mode or liquid level measurement mode).
3. Single point normally on mode.
4. Single-point normally closed mode.
5. Single point normally open interval mode with large hysteresis loop.
6. Single-point normally closed interval mode with large hysteresis loop.
7. Whether the normally open mode is detected.
8. Whether the normally closed mode is detected.
About RS485 output model products. Description of
There are three modes of operation,
1: Automatic measurement mode, the sensor continuously measures the liquid level and distance, and the user reads the measurement results through the 485 interface at any time.
2: The user does not initiate a 485 communication, the sensor will actively initiate a measurement and report the result.
3: Sleep mode, the product goes into sleep mode, the user first wakes up the sensor through the 485 interface, and then initiates a measurement and obtains the results before the sensor sleeps again.
Click here to learn more
|   | 
 4 - 20mA Output Fluid Level Meter Hygienic Tuning Fork Densitometer Insulation Resistance
                                                                                    
                        
                        
                        
                                                            4 - 20mA Output Fluid Level Meter Hygienic Tuning Fork Densitometer Insulation Resistance
                                                    
                        
                     High accuracy Submersible Water Liquid Level Sensor Transmitter For power, pharmaceutical, water supply and drainage
                                                                                    
                        
                        
                        
                                                            High accuracy Submersible Water Liquid Level Sensor Transmitter For power, pharmaceutical, water supply and drainage
                                                    
                        
                     High Frequency Radar Fluid Level Meter Hot Water Level Sensor No Pollution
                                                                                    
                        
                        
                        
                                                            High Frequency Radar Fluid Level Meter Hot Water Level Sensor No Pollution
                                                    
                        
                     70m Measuring Range Radar Type Level Transmitter 26GHz Frequency High Accuracy
                                                                                    
                        
                        
                        
                                                            70m Measuring Range Radar Type Level Transmitter 26GHz Frequency High Accuracy
                                                    
                        
                     High Speed Fluid Level Meter Radar Level Transmitter Small Antenna Size Easy To Install
                                                                                    
                        
                        
                        
                                                            High Speed Fluid Level Meter Radar Level Transmitter Small Antenna Size Easy To Install
                                                    
                        
                     Hygienic Liquid Storage Fluid Level Meter High Frequency Non Contact Level Gauge
                                                                                    
                        
                        
                        
                                                            Hygienic Liquid Storage Fluid Level Meter High Frequency Non Contact Level Gauge
                                                    
                        
                     26GHz Frequency Fluid Level Meter IP67 Protection For Strong Corrosive Liquid
                                                                                    
                        
                        
                        
                                                            26GHz Frequency Fluid Level Meter IP67 Protection For Strong Corrosive Liquid
                                                    
                        
                     KUS550 Strong Signal Anti Corrosion Fluid Level Meter PTFE Tank Level Ultrosonic level Sensor
                                                                                    
                        
                        
                        
                                                            KUS550 Strong Signal Anti Corrosion Fluid Level Meter PTFE Tank Level Ultrosonic level Sensor
                                                    
                        
                     Digital RS485 Ultrasonic Water Level Pressure Sensor Low Power Consumption
                                                                                    
                        
                        
                        
                                                            Digital RS485 Ultrasonic Water Level Pressure Sensor Low Power Consumption
                                                    
                        
                     RS485 Output Explosion Proof Ultrasonic Water Level Meter High Precision With ABS Probe
                                                                                    
                        
                        
                        