Sign In | Join Free | My entremaqueros.com |
|
Categories | Redundant Power Supply Module |
---|---|
Brand Name: | Schneider |
Model Number: | 140DAO84210 |
Place of Origin: | FR |
MOQ: | 1 |
Price: | negotiable |
Payment Terms: | T/T, Western Union |
Supply Ability: | 100 |
Delivery Time: | 2-3 work days |
Packaging Details: | New in original box |
Brand: | Schneider |
Model: | 140DAO84210 |
Palce of Origin: | FR |
Series: | Quantum I/O |
Module Format: | Standard |
Voltage drop: | 1.5V |
Discrete output number: | 16 |
Company Info. |
Shenzhen Wisdomlong Technology CO.,LTD |
Verified Supplier |
View Contact Details |
Product List |
Redundant Power Supply Module SCHNEIDER AUTOMATION 140-DAO-842-10
OUTPUT MODULE 140DAO84210
Manufacturer: | Modicon Quantum |
Series: | Quantum I/O |
Weight: | Ask |
Product or component type: | AC discrete output modules |
Discrete output number: | 16 |
Group of channels: | 4 groups of 4 channels |
Supply frequency: | 47...63 Hz |
Voltage drop: | 1.5 V |
Discrete output voltage: | 83...253 V AC |
Addressing requirement: | 1 output word |
Absolute maximum output: | 400 Vrms 1 cycle AC |
300 Vrms for 10 s AC | |
Minimum load: | 5 A |
Minimum load current: | 4 A rms per group |
4 A rms 85...132 V per output | |
3 A rms 170...253 V per output | |
2.5 mA rms 230 Vrms off state leakage per output | |
2 mA rms 115 Vrms off state leakage per output | |
16 A rms per module | |
1 mA rms off state leakage per output | |
Surge current: | <= 45 A during 1 cycle per group |
<= 30 A during 2 cycles per group | |
<= 30 A during 1 cycle per point | |
<= 25 A during 3 cycles per group | |
<= 20 A during 2 cycles per point | |
<= 10 A during 3 cycles per point | |
DV/Dt: | 400 V/ms |
Response time: | <= 0.5 ms at state 1 to state 0 |
<= 0.5 ms at state 0 to state 1 | |
Fault indication: | Blown fuse |
Loss of field power | |
Protection type: | Internal by RC filter |
Internal output protection by 5 A fuse | |
Power dissipation: | 1.85 + (1.1 V x total module load current) |
Marking: | CE |
Local signalling: | 16 LEDs green input status |
1 LED red external fault detected (F) | |
1 LED green bus communication is present (Active) | |
Bus current requirement: | 350 mA |
Module format: | Standard |
OTHER SUPERIOR PRODUCTS
Yasakawa Motor, Driver SG- | Mitsubishi Motor HC-,HA- |
Westinghouse Modules 1C-,5X- | Emerson VE-,KJ- |
Honeywell TC-,TK- | GE Modules IC - |
Fanuc motor A0- | Yokogawa transmitter EJA- |
Similar Products
140ACI03000
140ACI04000
140ACO02000
140ACO13000
140ARI03010
140AMM09000
140AVI03000
140AVO02000
140ATI03000
140DDI35300
140DDI84100
140DDI85300
140DAI74000
140DAI75300
140DAO85300
140DAO84000
140DAO84210
140DDO35300
140DDO84300
Estimated Shipping Size
Dimensions: 2" x 4" x 10" (5 cm x 10 cm x 25 cm)
Weight: 1 lbs 2 oz (0.51 kg)
Schneider 140-DAO-842-10 Output Module 140DAO84210 Sealed
PN: 140-DAO-842-10
140DAO84210
Schneider Automation Inc
PN: 140 DAO 842 10
140DAO84210
Output Module
AC Out 100-230V 4X4
TSX Quantum
112698
UPC Number: 3 595861 126985
PV: 00
RL: 77
DOM: 03-2002
Sealed In Factory Packaging
SIL
NOTE: For complete definitions and parameters related to SIL
ratings refer to IEC 61508, "Functional safety of
electrical/electronic/programmable electronic safety related
systems". Provided here is a partial definition.
safety integrity level
discrete level (1 out of a possible 4) for specifying the safety
integrity requirements of the safety functions to be allocated to
the E/E/PE safety-related systems, where safety integrity level 4
has the highest level of safety integrity and safety integrity
level 1 has the lowest
(Definition IEC 61508)
SIL2 project (application)
A project (application) that uses a Quantum Safety PLC (140 CPU 651
60S V1.00 or 140 CPU 671 60S V1.00) to implement Safety Functions
in a Safety-Related System.
SIL3 project (application)
A project (application) that uses a Quantum Safety PLC (140 CPU 651
60S V2.00 or 140 CPU 671 60S V2.00) to implement Safety Functions
in a Safety-Related System.
SIR
Safety Integrity requirement
Safety Integrity requirements are derived from a risk assessment
and describe the likelihood of a Safety Function to be performed
satisfactorily, for instance the degree of certainty necessary for
the Safety Function to be carried out.
sniffingreading the configuration out of a PLC
SRS
safety requirements specification
specification containing all the requirements of the safety
functions that have to be performed by the safety-related systems
(Definition IEC 61508)
![]() |