| Sign In | Join Free | My entremaqueros.com |
|
| Categories | ABB Module |
|---|---|
| Brand Name: | ABB Module |
| Model Number: | PU514 3BSE013062R1 |
| Certification: | CO.CQ |
| Place of Origin: | Sweden |
| MOQ: | 1 |
| Price: | inquiry |
| Payment Terms: | T/T |
| Supply Ability: | 10 pieces a day |
| Delivery Time: | today |
| Packaging Details: | new and original with factory sealed |
| Manufacture Year: | 2016 |
| Control System: | ABB Module System |
| Application: | Nuclear Power Plant |
| lead time: | in stock |
| description: | PU514 3BSE013062R1 ABB PU514 3BSE013062-R1 board |
| Weight: | 4lbs |
| Company Info. |
| MOORE AUTOMATION LIMITED |
| Verified Supplier |
| View Contact Details |
| Product List |
ABB Module PU514 3BSE013062R1 ABB PU514 3BSE013062-R1 board For new products
Product Description:
Temperatures that exceed the measuring range cause the overflow
numerical value of +32767. If the measured value is below the
range, the underflow numerical value of -32767 is set. In case of a
detected open-circuit the numerical value of 32767 is set. If the
sensor is short-circuited, the numerical value of -32767 is set. If
the open-circuit or short-circuit monitoring is configured,
the detected error is displayed by the red LED Ovl as long as it is
present. In the PLC system an error message is stored (FK4, error
number 9). In order to avoid error messages with unused analog
inputs,
it is useful, not to configure this channels for Pt100.In order to
avoid measurement errors, it is absolutely necessary, to lead the
cores to the Pt100 sensors in the same cable. The cores must have
the same cross section.

Related Product Recommendation:
|
Product's Character:
Differential inputs are very useful, if analog sensors are used
which are remotely non-isolated (e.g. the minus terminal is
remotely earthed). Since the earthing potential is not exactly the
same as
AGND1, it has to be measured bipolar in order to compensate
measuring errors. Additionally, in case of singlepole
configuration, AGND1 would be connected directly to the remote
earth potential. This would cause inadmissable (and possibly
dangerous) earthing loops. In all configurations using differential
inputs two adjacent analog inputs belong together (e.g. EW 6,00 and
EW 6,01). For configuration, both inputs must be configured for the
desired operating mode, see configuration table Fig. The measured
value is calculated by subtraction. The value of the channel with
the lower address is subtracted

CMA 121 3DDE 300 401 DC Power Supply Module ABB
CMA 122 CPU Card ABB
CMA 123 CMA123 Display Card ABB
CMA 124 Measuring Card ABB
CMA 125 Generator Card ABB
CMA 126 Interface Card ABB
CMA 132 Generator Relay Terminal Board ABB
CMA 133 3DDE 300 413 Terminal board ABB
CMA 136 Generator Relay Terminal Board ABB
CMA 137 Connection Module ABB
CMA131 Servo-motor Drive Encoder Module ABB
CMA135 Diesel Start Stop Automatic Module ABB
CMM11 Condition Monitoring Module ABB
CP501 1SBP260170R1001 Text Display ABB
CP502 1SBP 260171 R1001 Text Display Panel ABB
CP503 1SBP 260172 R1001 Text Display Panel ABB
CP511 1SBP 260173 R1001 Operator Panel - Graphics and Text ABB
CP512 1SBP 260174 R1001 Operator Panel - Graphics and Text ABB
CPU86-NDP 57287586 CPU Processor Board ABB
CS512 3BUR980009R1 CS512 DCN Interface Module ABB
CS513 3BSE000435R1 MasterBus 300E Communications Module ABB
CS513K01 3BSE004772R1 MasterBus 300E Communications Module ABB
CS513K02 3BSE004773R1 MasterBus 300E Communications Module ABB
CS513K04 3BSE055760R1 MasterBus 300/300E Comm. Interface for RJ45
ABB
CSC01 Loop Command Sequence Controller ABB
CT 370a GJR2 237500 R1, GJR2237500R0001 CT 370a Module ABB
CT 5536a HEIE420807R1, HEIE420807R0001 CT5536a Module ABB
CTT01 Configuration Tuning Terminal Bailey
CTT02 Handheld Configurator Tuning Terminal ABB
DAC85-10B 57574825BA ULMA D/A Converter Module ABB
DAI 01 P 37131-4-0369628 DAI01 Analog Input Module ABB
DAI 02 0369630M DAI 02 Analog Input Module ABB
DAI 03 P 37141-4-0369631 Analog Input Module ABB
DAI 04 P37131-4-0369632 Analog Input Module ABB
DAI 05 P 37131-4-0336025 DAI 05 Analog Input Module ABB
DAO 01 P 3717-4-0369629 DAO 01 Analog Output Module ABB
The use of the product:
1. Improve efficiency
2.new and original
3.Risk-free guarantee, 60 days refund. If the item you purchase
from our store are not of perfected quality, simply return them to
us for replacement or refund
1.mission reduction
2.We keep more than 10 thousands Transistors in warehouse, it could
cut lead time of most items.
3.Customer service in 1-4 hours. If there's any question, please
contact with our sales.
1.Q: Can you provide discount ?
A: Yes, we are glad to offer you dicount if you order more than 1
piece .
1.Q: Are the P/N latest?
A: Yes. All P/N are latest and date codes are in 2016 or 2017.
2.Q: What is the capacity of your warehouse?
A: We have 1-2Mil USD safe stocks and 3 warehouses, which located
Xiamen,
Shenzhen & Hongkong.
Send your Inquiry details in the Below, Click "Send" Now!
Email :sales@mooreplc.com
Q Q: 2851195450
Skype: miyazheng520
Mobile:86-18020776792 ( what's app )
|