| Sign In | Join Free | My entremaqueros.com |
|
| Categories | Environmental Test Chamber |
|---|---|
| Brand Name: | Pride |
| Model Number: | PHL-80A |
| Place of Origin: | China |
| MOQ: | 1 |
| Price: | negotiation |
| Payment Terms: | L/C, T/T, Western Union, MoneyGram |
| Delivery Time: | 10-15 work days |
| Packaging Details: | wooden case |
| System: | Balanced Temperature Control System |
| Temp.fluctuation: | ≤0.5℃ |
| Heating up time: | 0℃ ~ +100℃ within 20 min |
| Pull down time: | 20℃ ~ 0℃ within 20 min |
| Power: | AC220V/380V、50/60HZ |
| Exterior material: | Cold rolled plate paint |
| Temp.stability: | ±0.2℃ |
| Company Info. |
| Shenzhen Pride Instrument Inc. |
| View Contact Details |
| Product List |
LCD Touch Screen Environmental Test Chamber With Programmable Highand Low Temperature
● The box body is processed shape using CNC machine tool, beautiful
appearance,and uses no reaction door handles, easy to operate, safe
and reliable.
● Adopted built-in fluorescent lamp,the rectangular viewing window
consists of glass with a heat generator,which prevents blur and
saves wiper operation so that you can always observe the test under
the best conditions.
● Available in Chinese and English LCD touch screen,easy operation
and program.
● Able to display the relative data and information of the whole
operating system in running monde,graphic
display,precautions,maintenance and trouble shooting.
● The siracco fan motor provides greater cyclic airflow to avoid
dead corner in the chamber,so as to obtain a uniform distribution
of temperature and humidity.
● The heating, cooling system completely independent can improve
efficiency, reduce cost of test , increase life expectancy and
reduce the failure rate.
Specifications: 0℃ ~ +100(150℃)
| Model | PHL-80A | PHL-150A | PHL-225A | PHL-416A | PHL-800A | PHL-1000A | ||
| Interior dimensions (mm) | W | 400 | 500 | 500 | 700 | 1000 | 1000 | |
| H | 500 | 600 | 750 | 850 | 1000 | 1000 | ||
| D | 400 | 500 | 600 | 700 | 800 | 1000 | ||
| Exterior dimensions (mm) | W | 930 | 1030 | 1080 | 1230 | 1530 | 1530 | |
| H | 1310 | 1410 | 1620 | 1660 | 1810 | 1810 | ||
| D | 910 | 1010 | 1220 | 1410 | 1610 | 1510 | ||
| Interior Volume(L) | 80 | 150 | 225 | 416 | 800 | 1000 | ||
| System | Balanced Temperature Control System | |||||||
| environment temp.&humi.range | +5℃ ~ +35℃ / <85%RH | |||||||
| Temp.range | -0℃ ~ +100(150℃) (A=0℃ B=-20℃ C=-40℃ D=-70℃ optional) | |||||||
| Temp.fluctuation | ≤0.5℃ | |||||||
| Temp.uniformity | ≤2.0℃ | |||||||
| Temp.stability | ±0.2℃ | ±1.5℃ | ||||||
| Heating up time | 0℃ ~ +100℃ within 20 min | |||||||
| Pull down time | 20℃ ~ 0℃ within 20 min | |||||||
| Power | AC220V/380V,50/60HZ | |||||||
| Exterior material | Cold rolled plate paint | |||||||
| Interior material | Stainless steel plate | |||||||
| Insulation | Polyurethane;fire retardant;100k insulation rockwool | |||||||
| Refrigeration system | Hermetic compressor, single stage refrigeration system | |||||||
| Heating system | Stainless steel thermal heaters | |||||||
| Controller | TEMI-880 Touch panel | |||||||
| Safety devices | Overheat protector,Over voltage and phase shift protector,Compressor overload and high pressure protector,Buzzer alarm | |||||||
| Accessories | Viewing window,Chamber lamp,Cable port ø50mm,Stainless steel netting bracket 2sets | |||||||
* At 20℃ Cambient temperature or 25℃ water temperature and
non-loaded.
* The sensor should be located at a distance of 1/6 of the interior
dimension from the interior chamber wall.
* The above specifications are for reference only,the actual
specifications for the main quotaion.
* Can according to customer requirements of size, special order
Specifications: -20℃ ~ +100(150℃)
| Model | PHL-80B | PHL-150B | PHL-225B | PHL-416B | PHL-800B | PHL-1000B | ||
| Interior dimensions (mm) | W | 400 | 500 | 500 | 700 | 1000 | 1000 | |
| H | 500 | 600 | 750 | 850 | 1000 | 1000 | ||
| D | 400 | 500 | 600 | 700 | 800 | 1000 | ||
| Exterior dimensions (mm) | W | 930 | 1030 | 1080 | 1230 | 1530 | 1530 | |
| H | 1310 | 1410 | 1620 | 1660 | 1810 | 1810 | ||
| D | 810 | 910 | 1120 | 1210 | 1310 | 1510 | ||
| Interior Volume(L) | 80 | 150 | 225 | 416 | 800 | 1000 | ||
| System | Balanced Temperature Control System | |||||||
| environment temp.&humi.range | +5℃ ~ +35℃ / <85%RH | |||||||
| Temp.range | -20℃ ~ +100(150℃) (A=0℃ B=-20℃ C=-40℃ D=-70℃ optional) | |||||||
| Temp.fluctuation | ≤0.5℃ | |||||||
| Temp.uniformity | ≤2.0℃ | |||||||
| Temp.stability | ±0.2℃ | ±1.5℃ | ||||||
| Heating up time | -20℃ ~ +100℃ within 35 min | |||||||
| Pull down time | 20℃ ~ -20℃ within 45 min | |||||||
| Power | AC220V/380V,50/60HZ | |||||||
| Exterior material | Cold rolled plate paint | |||||||
| Interior material | Stainless steel plate | |||||||
| Insulation | Polyurethane;fire retardant;100k insulation rockwool | |||||||
| Refrigeration system | Hermetic compressor,cascade refrigeration system | |||||||
| Heating system | Stainless steel thermal heaters | |||||||
| Controller | TEMI-880 Touch panel | |||||||
| Safety devices | Overheat protector,Over voltage and phase shift protector,Compressor overload and high pressure protector,Buzzer alarm | |||||||
| Accessories | Viewing window,Chamber lamp,Cable port ø50mm,Stainless steel netting bracket 2sets | |||||||
* At 20℃ Cambient temperature or 25℃ water temperature and
non-loaded.
* The sensor should be located at a distance of 1/6 of the interior
dimension from the interior chamber wall.
* The above specifications are for reference only,the actual
specifications for the main quotaion.
* Can according to customer requirements of size, special order.
Specifications: -40℃ ~ +100(150℃)
| Model | PHL-80C | PHL-150C | PHL-225C | PHL-416C | PHL-800C | PHL-1000C | ||
| Interior dimensions (mm) | W | 400 | 500 | 500 | 700 | 1000 | 1000 | |
| H | 500 | 600 | 750 | 850 | 1000 | 1000 | ||
| D | 400 | 500 | 600 | 700 | 800 | 1000 | ||
| Exterior dimensions (mm) | W | 930 | 1030 | 1080 | 1230 | 1530 | 1530 | |
| H | 1310 | 1410 | 1620 | 1660 | 1810 | 1810 | ||
| D | 810 | 910 | 1120 | 1210 | 1310 | 1510 | ||
| Interior Volume(L) | 80 | 150 | 225 | 416 | 800 | 1000 | ||
| System | Balanced Temperature Control System | |||||||
| environment temp.&humi.range | +5℃ ~ +35℃ / <85%RH | |||||||
| Temp.range | -40℃ ~ +100(150℃) (A=0℃ B=-20℃ C=-40℃ D=-70℃ optional) | |||||||
| Temp.fluctuation | ≤0.5℃ | |||||||
| Temp.uniformity | ≤2.0℃ | |||||||
| Temp.stability | ±0.2℃ | ±1.5℃ | ||||||
| Heating up time | -40℃ ~ +100℃ within 40 min | |||||||
| Pull down time | 20℃ ~ -40℃ within 60 min | |||||||
| Power | AC220V/380V,50/60HZ | |||||||
| Exterior material | Cold rolled plate paint | |||||||
| Interior material | Stainless steel plate | |||||||
| Insulation | Polyurethane;fire retardant;100k insulation rockwool | |||||||
| Refrigeration system | Hermetic compressor,cascade refrigeration system | |||||||
| Heating system | Stainless steel thermal heaters | |||||||
| Controller | TEMI-880 Touch panel | |||||||
| Safety devices | Overheat protector,Over voltage and phase shift protector,Compressor overload and high pressure protector,Buzzer alarm | |||||||
| Accessories | Viewing window,Chamber lamp,Cable port ø50mm,Stainless steel netting bracket 2sets | |||||||
* At 20℃ Cambient temperature or 25℃ water temperature and
non-loaded.
* The sensor should be located at a distance of 1/6 of the interior
dimension from the interior chamber wall.
* The above specifications are for reference only,the actual
specifications for the main quotaion.
* Can according to customer requirements of size, special order.
Specifications: -70℃ ~ +100(150℃)
| Model | PHL-80D | PHL-150D | PHL-225D | PHL-416D | PHL-800D | PHL-1000D | ||
| Interior dimensions (mm) | W | 400 | 500 | 500 | 700 | 1000 | 1000 | |
| H | 500 | 600 | 750 | 850 | 1000 | 1000 | ||
| D | 400 | 500 | 600 | 700 | 800 | 1000 | ||
| Exterior dimensions (mm) | W | 930 | 1030 | 1080 | 1230 | 1530 | 1530 | |
| H | 1310 | 1410 | 1620 | 1660 | 1810 | 1810 | ||
| D | 810 | 910 | 1120 | 1210 | 1310 | 1510 | ||
| Interior Volume(L) | 80 | 150 | 225 | 416 | 800 | 1000 | ||
| System | Balanced Temperature Control System | |||||||
| environment temp.&humi.range | +5℃ ~ +35℃ / <85%RH | |||||||
| Temp.range | -70℃ ~ +100(150℃) (A=0℃ B=-20℃ C=-40℃ D=-70℃ optional) | |||||||
| Temp.fluctuation | ≤0.5℃ | |||||||
| Temp.uniformity | ≤2.0℃ | |||||||
| Temp.stability | ±0.2℃ | ±1.5℃ | ||||||
| Heating up time | -70℃ ~ +100℃ within 60 min | |||||||
| Pull down time | 20℃ ~ -70℃ within 90 min | |||||||
| Power | AC220V/380V,50/60HZ | |||||||
| Exterior material | Cold rolled plate paint | |||||||
| Interior material | Stainless steel plate | |||||||
| Insulation | Polyurethane;fire retardant;100k insulation rockwool | |||||||
| Refrigeration system | Hermetic compressor,cascade refrigeration system | |||||||
| Heating system | Stainless steel thermal heaters | |||||||
| Controller | TEMI-880 Touch panel | |||||||
| Safety devices | Overheat protector,Over voltage and phase shift protector,Compressor overload and high pressure protector,Buzzer alarm | |||||||
| Accessories | Viewing window,Chamber lamp,Cable port ø50mm,Stainless steel netting bracket 2sets | |||||||
* At 20℃ Cambient temperature or 25℃ water temperature and
non-loaded.
* The sensor should be located at a distance of 1/6 of the interior
dimension from the interior chamber wall.
* The above specifications are for reference only,the actual
specifications for the main quotaion.
* Can according to customer requirements of size, special order.
|