| Sign In | Join Free | My entremaqueros.com |
|
| Categories | LINK-PP Magnetics |
|---|---|
| Brand Name: | LINK-PP |
| Model Number: | LP6062ANL |
| Certification: | UL,RoHS,Reach,ISO |
| Place of Origin: | Guangdong,China |
| MOQ: | 400/2000/10K/25K |
| Price: | $0.06-$1.2 |
| Payment Terms: | TT,NET30/60/90 Days |
| Supply Ability: | 3KK/Month |
| Delivery Time: | in Stock Ship Today |
| Packaging Details: | T&R |
| P/N: | LP6062ANL |
| Type: | PoE+ LAN Transformer |
| Hipot: | 1500Vrms 1mA 1Second |
| Dimension: | 17.60x12.20x6.00mm |
| Max reflow temperature: | 250°C for 5 seconds |
| Compatible Brands: | Pulse |
| Data Rate: | 1000Base-T |
| Number of Channels/Ports: | Single |
| PoE: | PoE+ |
| Mounting Type: | SMT |
| Turns Ratio: | 1:1 |
| Operating Temperature Range: | -40°C to +85°C |
| Company Info. |
| LINK-PP INT'L TECHNOLOGY CO., LIMITED |
| Verified Supplier |
| View Contact Details |
| Product List |
The LINK-PP LP6062ANL is a high-performance Gigabit Ethernet LAN transformer module designed for 10/100/1000BASE-T applications with PoE+ (IEEE 802.3at) support. Engineered for reliability, signal integrity, and EMI performance, this 24-pin magnetic module is ideal for networking equipment, SOHO devices, LOM designs, industrial systems, and telecom applications.
| Parameter | Specification |
|---|---|
| Turns Ratio (TX/RX) | 1CT:1CT ±5% |
| OCL (100 kHz, 100 mV, 11 mA) | ≥ 350 µH |
| Insertion Loss (1–100 MHz) | ≤ –1.2 dB |
| Return Loss | 1–30 MHz: ≥ –16 dB30–60 MHz: ≥ –12 dB60–80 MHz: ≥ –10 dB80–100 MHz: ≥ –8 dB |
| Crosstalk (1–100 MHz) | ≥ –30 dB |
| Common-Mode Rejection (1–100 MHz) | ≥ –30 dB |
| Balance DC Line Current | Max 720 mA @ 57 VDC continuous |
| Hipot | 1500 Vrms, 1mA, 1 sec |
| Operating Temperature | −40°C to +85°C |

LINK-PP products comply with major global standards, ensuring safety, reliability, and environmental responsibility:
Our high-precision production flow ensures stable electrical performance and consistent quality across all LAN Magnetics & RJ45 solutions.
State-of-the-art test systems guarantee every LAN transformer meets industry-level EMI, signal integrity, and reliability standards.
|