Sign In | Join Free | My entremaqueros.com
entremaqueros.com
Products
Search by Category
Home > Fruit Grafts, Seedlings & Rootstocks >

LCD Display Mini Digital Clamp Meter Autormatic Range 600V

Categories Digital Clamp Multimeter
Brand Name: CHX
Model Number: CHX-CM001
Certification: CE, RoHS
Place of Origin: CHINA
MOQ: 10pc
Price: Negotiation
Payment Terms: T/T, Western Union,Paypal,L/C
Supply Ability: 50000pcs/month
Delivery Time: 5-35days
Packaging Details: 1pcs/gift box, 30~50pcs/ctn
Mode: CHX-CM001
Display: LCD display , the maximum reading of 1999
Measurement principle: double integral A/D conversion
Range selection: Automatic
Measurement rate: (2,5 times to 3 times) / sec
Dimensions: 208mm × 79mm x 36mm
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    LCD Display Mini Digital Clamp Meter Autormatic Range 600V


    Wholesale Portable Digital Noise Decibel Sound Level Meter


    GUARANTEE:


    Draper tools have been carefully tested and inspected before shipment and are guaranteed to be free from defective materials and workmanship.


    Should the tool develop a fault,please return the complete tool to your nearest distributor or contact Draper Tools Limited. Chandler's Ford,Eastleigh,Hampshire, SO53 1YF, England.


    Telephone Sales Desk: (023) 8049 4333 or Product Helpline (023) 8049 4344. A proof of purchase must be provided with the tool.
    I upon inspection it is found that the fault occurring is due to defective materials or workmanship,repairs will be carried out free of charge,This quarantee period covering parts/labour is 12 months from the date of purchase except where tools are hired oit when the quarantee period is 90 days from the date of purchase. This guarantee does not apply to normal wear and tear, nor does it cover any damage caused by misuse, careless or unsafe handling, alterations, accidents, or repairs attempted or made by any personnel other than the authorised Draper warranty repair agent.


    Note; If the tool is found not to be within the terms of warranty, repairs and carriage charges will be quoted and made accordingly.
    This guarantee applies in lieu of any other gquarantee expressed or implied and variations of its terms are not authorised.
    Your Draper guarantee is not effective unless you can produce upon request a dated receipt or invoice to verify your proof of purchase within the guarantee period.


    Please note that this quarantee is an additional benefit and does not affect your statutory rignts.
    Draper Tools Limited.


    GENERAL SPECIFICATIONS


    Voltage input and ground between the maximum voltage CAT l 600V= & 600V-
    Display: LCD display, the maximum reading of 1999

    Measurement principle: double integral A/D conversion

    Range selection: Autormatic
    Measurement rate: (2,5 times to 3 times) / sec
    Unit display: with the function, the unt of electricity symbol dsplay

    Polarity display: Negative polarity input shows"—"

    Over range display: "OL"
    Data hold function: LCD display""
    Low battery indicator. LCD upperleft shows ""

    Power supply battery: DC1.5V X3 SIZE AAA

    Dimensions: 208mm × 79mm x 36mm

    Weight no more than 333g (including battery) Jaw opening

    maximum size: 36mm

    Oporating lemperature;5"C-35 C

    Storage tomperature:-10 ℃-50 ℃C


    SAFETY PRECAUTIONS


    The instrument strictly follows the GB4793 electronic measuring instrument safety requirements IEC61010-1 and IEC1010-2-032 safety standards for the design and production, in line with double insulation,over-voltage CATIII 600V and pollution level 2 safety standards. Safe working hablits
    To avoid possible electric shock or personal injury,and to avoid damage to the instrument
    or the object to be measured, use the meter in the following ways:
    · Inspect the instrument. Do not use the instrument if the case is damaged. Check for
    cracks or missing plastic parts. Pay particular attention to the insulating layer of the Cconnector.
    · Inspect the test leads for insulation damage or bare metal. Check the continuity of the
    test leads.If the test leads are damaged, replace them before using the instrument. Lse the instrumont to measure a known yolaoe to make sure the instrumont operates
    normally. Do not use if the instrument is working abnormally. Protection facilities may have been damaged. If in doubt, the instrument should be sent for maintenance.
    · Do not apply any yoltage beyond the rated voltage indicated on the meter between any
    terminal and earth ground.
    · Warning; When working above 30V use caution not to touch exposed contacts due to
    risk of electric shock. Only use the approved probes or clamps.
    · Measurements must be made with the correct jack, function and range.· Do not use the instrument near explosive gases, vapours or dust.
    · When using the test leads, keep your fingers behind the test lead protector.
    . When connectina.first connect the common testlead. and then connect the live test
    lead,When disconnect, the live test lead and then disconnect the common test lead,.Before vou test tho resistance.continuity and diodes. you must first cut off the power.
    and discharae all the capacitors,
    · If the meter is not used in accordance with the instructions. the safety protection
    provided by the instrument may be impaired or invalidated.
    · Ensure the instrument is switched off when opening the battery cover.


    When the battery under voltage indicator "" lights up, immediately replace the battery, When the battery power is low, the meter may produce incorrect readings resulting in electric shock and personal injiury, DO NOT mix new and old batteries and do not use re-chargeable batteries, Before opening the battery cover,the test leads must be rermoved from the instrument. Please use a soft coth to clean instrument case,do not use abrasives or solvents.

    Quality LCD Display Mini Digital Clamp Meter Autormatic Range 600V for sale
    Send your message to this supplier
     
    *From:
    *To: SHENZHEN XISHEN DEVELOPMENT COMPANLY LIMITED
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0

    Friendly Links: www.everychina.com

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2024 entremaqueros.com. All rights reserved.