Sign In | Join Free | My entremaqueros.com
entremaqueros.com
Products
Search by Category
Home > Rubber Raw Materials >

Standard Source Electrical Calibration Equipment 20~500Hz With Liquid Crystal Display

Categories Electrical Calibration Equipment
Brand Name: XL
Model Number: XL-9200
Certification: CE
Place of Origin: China
MOQ: negotiate
Price: negotiate
Payment Terms: L/C, D/A, D/P, Western Union, MoneyGram
Supply Ability: 800 pcs per month
Delivery Time: 3~4 weeks
Packaging Details: external packing:carton or non wooden box;cushion packing:EPE foam
Product Name: Electrical Calibration Equipment
DC voltage output: 0~1000V
DC current output: 0~250A
Small signal output: 0~5V
Ripple output: 20~500Hz
Accuracy level: 0.05
power error: 0.1%
Small signal: Uo≤1V:≤1mA
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Standard Source Electrical Calibration Equipment 20~500Hz With Liquid Crystal Display

    Standard Source Electrical Calibration Equipment With Liquid Crystal Display


    XL-9200 DC Electrical Calibration Equipment is the latest standard voltage and current source designed and developed by Shenzhen Xinglong Technology Co., Ltd., which is based on the current national standard for DC energy meter verification and adopts the latest technology. The main components are imported industrial grade devices, which can support 0~200ADC high current signal, the accuracy level is better than 0.05%; 0~1000V DC voltage output, accuracy grade is better than 0.02%; 0~5V DC voltage analog shunt Output, accuracy class 0.05%, and support voltage, current output ripple superposition function, can be used for DC load meter virtual load verification, ripple interference test, or as a separate voltage standard source, current standard source, power standard source The device has passed the test of Shenzhen Metrology Institute.
    The device adopts 800×600 liquid crystal display, the interface is clear and simple, the operation is convenient, and the visual effect is good. The core module uses 32-bit high-speed DSP combined with adaptive Lagrangian interpolation algorithm to eliminate the hardware non-synchronization error of DC ripple. Waveform quantization uses 32-bit dual modulation output technology to ensure high output accuracy. The output has overcurrent and overheat protection, which is safe and reliable.


    Product Name:Electrical Calibration EquipmentDC Voltage Output:0~1000V
    DC Current Output:0~250ASmall Signal Output:0~5V
    Ripple Output:20~500HzAccuracy Level:0.05
    Power Error:0.1%Small Signal:Uo≤1V:≤1mA
    1. Main functions of Electrical Calibration Equipment
      Main function Description
      DC voltage output Supports 0~1000V DC voltage output with an accuracy of up to two ten thousandths
      DC current output Supports 0~250A DC current output with accuracy up to five ten thousandths
      Small signal output Supports 0~5V DC voltage output with accuracy better than 5/10,000
      Ripple output supports 20~500Hz ripple output
      DC electric energy meter verification Supports virtual load meter verification of DC energy meter
      Error calculation Support automatic error calculation of upper software
      Start test support
      Latent test support
      Ripple test support
      Generate report support
    2. Technical indicators of Electrical Calibration Equipment
      No. Name Indicator range
      1 Accuracy level 0.05
      2 Voltage, current, small signal amplitude accuracy Voltage: 0.02% RD + 10mV
      Current: 0.05% RD+20uA
      Small signal: Uo ≤ 4 mV: 0.05 % RD +10 uV;
      4 mV ≤ Uo ≤ 5 V: 0.05 % RD
      3 power error 0.1%
      4 output phase number 1 phase voltage, 1 phase current
      1 way small signal
      5 gear setting voltage: 65V, 250V, 500V, 750V, 1000V
      Current: 0.02A, 0.2A, 1A, 5A, 10A, 20A, 60A, 200A
      Small signal: 2.5mV, 20mV, 100mV, 1V, 5V
      6 Output stability Voltage: better than 0.01%, typically 0.005%
      Current: better than 0.01%, typically 0.005%
      Small signal: better than 0.02%
      7 Output power Current: 200VA maximum, port voltage up to 2V
      Voltage: up to 100VA, output current 100mA
      Small signal: Uo≤1V:≤1mA
      1V≤Uo≤ 5V:≤10mA
      8 Ripple superposition Frequency: 20~500Hz
      Ripple voltage accuracy: 20-500Hz: <0.5%
      Ripple current accuracy: 20-200Hz: <1%
      200-500Hz: <5%
      9 Long-term stability Voltage and current: ±100PPM/year

    3. Notes (Important)


    l Although the device has three inspected pulse input ports, only one of the inspected tables that are not isolated for voltage and current input can be calibrated at a time.
    l The voltage and current outputs of the device are isolated from each other, allowing the user to have a short contact between voltage and current during use, that is, only a single point connection of voltage and current is allowed.
    l The voltage output can be as high as 1000V, which is a threat to personal safety. Please pay attention to safety.

    Quality Standard Source Electrical Calibration Equipment 20~500Hz With Liquid Crystal Display for sale
    Send your message to this supplier
     
    From:
    To: XL Science And Technology Co. Ltd
    Subject:
    Message:
    Characters Remaining: (0/3000)
     
    Find Similar Products By Category:
    Inquiry Cart 0

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2019 entremaqueros.com. All rights reserved.