Brand Name: Power World
Model Number: #MG-030A-KFLWS
Certification: CE, IEC, EN14511
Place of Origin: China
MOQ: 1 pcs
Price: negotiation
Payment Terms: T/T or western Union, D/A, L/C, D/P, MoneyGram
Supply Ability: 10,000pcs per month
Delivery Time: 15-20 working days after received your payment
Packaging Details: Plywood package
Application: House heating & live hot water
Feature 1: Auto-swich Domestic Water to House Heating
Feature 2: Weekly Uperization
Work Condition: -25℃ to 43℃
Water Outlet: 35℃ to 60℃
COP: 3.97
Heating Outlet: 10.5kw
Power Input: 2.90kw
Compressor: COPELAND
Refrigerant: R407C/oem
Power Supply: 220-240V/50Hz
Noise in 1M: below 55 dB(A)
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    10.5kw Big Indoor Unit Two-piece Style Low Temperature Air to Water Heater Pump for House & Domestic Water Heating

    10.5kw Big Indoor Unit Two-piece Style Low Temp. Air to Water Heater Pump for House & Domestic Water Heating


    10.5kw Big Indoor Unit Two-piece Style Low Temp. Air to Water Heater Pump Features:


    1. Super low temperature working condition and outstanding defrosting design

    Big Indoor Unit with key configuration in the house and only fan+motor and evaperator outside in environment, EVI technology to strength its performance in cold area, especially during -2DegC to 3DegC and exceeding -25DegC ambient temperature, so as to supply hot water constantly for daily usage, house heating or 55DegC domestic water.


    2. Environmental friendly and safe
    Electric parts and water system is completely cut off, ensuring security water use, no pollution to the atmosphere and free of greenhouse effect and it is the safest water heater

    3. Wide climatic zone adaptability
    Our heat pumps with splinched design possess better climatic adaptability, can work from -25degrees to 43degrees.

    4. Energy-saving
    Heat pump water heater is a high efficient transferring heating equipment which is driven by electricity. The operating cost is only 1/4 of electric water heater, 1/3 of gas water heater.

    5. Automatic intelligent control system
    Adopting intelligent computerized automatic control system, no manual cost, easy to operate, convenient, make heat pump work safely and reliably.
    Control panel with modularized unit design can control more flexible heat pumps packs, with user-friendly
    operating system interface, easy to operate..

    6. Advanced testing methods
    Adopting world class Enthalpy potential laboratory to test heat pumps, except basic testing items, we also test heat pump in the ambient of temperature of -30℃ to test our heat pump performance.

    7. Widely used
    Heat pump is applied to hot water for household and commercial use like families, schools, hospitals, shower center, swimming pools, etc. and industrial use like electroplating, drying, etc.


    10.5kw Big Indoor Unit Two-piece Style Low Temp. Air to Water Heater Pump Specification:


    EVI Split Low Temperature Air Source Heat Pump

    Item No.

    #PF030-KFLWS-S

    #PF030-KFLWS

    #PF050-KFLWS

    Parameters

    Heating*

    Heating outlet

    10.5kW

    11.5 kW

    18.8 kW

    Input power

    2.7 kW

    2.9 kW

    4.8 kW

    Rated current

    12.4 A

    5.9 A

    9 A

    COP

    3.89

    3.97

    3.92

    Capacity (L/H)

    226

    247

    404

    Heating**

    Heating outlet

    8.4 kW

    9.1 kW

    15.0 kW

    Input power

    2.6 kW

    2.8 kW

    4.7 kW

    Rated current

    12.3 A

    5.8 A

    8.9 A

    COP

    3.23

    3.25

    3.19

    Capacity (L/H)

    157

    170

    280

    Heating***

    Heating outlet

    8.2 kW

    9.1 kW

    14.8 kW

    Heating input

    2.25 kW

    2.43 kW

    4 kW

    Rated current

    10.3A

    4.9 A

    7.5 A

    COP

    3.64

    3.74

    3.70

    Rated outlet hot water

    55℃

    55℃

    55℃

    Highest outlet hot water

    60℃

    60℃

    60℃

    Working condition

    -25℃~43℃

    IP Grade

    IPX4

    Anti-electric shock Rate

    I

    Noise in 1M (dB(A))

    ≤55

    ≤55

    ≤58

    N.W./G.W.(kg)

    140/155

    140/155

    190/210

    Diameter of pipe (mm)

    DN25

    DN25

    DN25

    Metel plate

    Galvanized steel/Spray/Gray

    Standard Configuration

    Outdoor unit size (W*D*H)

    830*490*1160

    1110*490*1260

    Indoor unit size (W*D*H)

    500*330*810

    500*330*810

    Compressor

    Copeland EVI

    Refrigerant

    R407C

    Power supply

    220V/50Hz

    380V/50Hz

    Condenser

    Efficient tank heat exchanger

    EVI heating exchanger

    Plate type MTB020-17

    Evaporator

    U-2/1200*550/φ9.52

    L-2/990*1200/φ9.52

    Four-way valve

    DSF-11

    DSF-20

    Expansion valve

    Danfoss /Emerson

    AC contactor

    (220V-25A)

    (220V-18A)

    Motor (with capacitance)

    50W*2(4μf*2)

    50W*2(4μf*2)

    90W*2(5μf)

    Fan

    φ420*2

    φ420*2

    φ490*2

    Controller

    Single System(Motorola IC)

    Low-voltage switch

    0.05/0.15MPa

    High-voltage switch

    3.0/3.6MPa

    Power line connect with unit

    3*2.5mm2

    3*4mm2+2*2.5mm2

    Package

    Polywood packing

    Heating* condition: Inlet water temp.15℃, outlet water temp.55℃, dry bulb temp.20℃, wet bulb temp.15℃.

    Heating** condition: Inlet water temp.9℃, outlet water temp. 55℃, dry bulb temp.7℃, wet bulb temp.6℃.

    Heating*** condition: Inlet water temp.9℃, outlet water temp.55℃, dry bulb temp.7℃, wet bulb temp.6℃.

    10.5kw Big Indoor Unit Two-piece Style Low Temp. Air to Water Heater Pump Applications:


    Business Organizations

    supermarket, large-scale shopping malls, exclusive agency, chain shops, large-scale
    sales, star-rated hotels, restaurants, travel agencies, pharmacy.

    Financial Organizations

    Banks, negotiable securities, funds, insurance companies, pawnshops;
    Non-profit Organizations: Telecommunications, post offices, hospital, schools;

    Public Places

    subway, airports, stations, gas stations, toll stations, bookstores, parks, exhibition halls,
    stadiums, museums, convention centers, ticket agencies, HR market, lottery centers;
    Real Estate Property: Apartments, villas, offices, commercial buildings, model rooms,
    property brokers;

    Entertainments

    Movie theaters, fitness halls, country clubs, clubs, massage rooms, bars, cafes,
    Internet bars, beauty shops, golf course


    10.5kw Big Indoor Unit Two-piece Style Low Temp. Air to Water Heater Pump COP Diagram:

    1)For domestic hot water heating


    2) For space heating


    10.5kw Big Indoor Unit Two-piece Style Low Temp. Air to Water Heater Pump installation Principle:


    10.5kw Big Indoor Unit Two-piece Style Low Temp. Air to Water Heater Pump Installation between Indoor & Outdoor Unit:



    10.5kw Big Indoor Unit Two-piece Style Low Temp. Air to Water Heater Pump Company Certificates:

    10.5kw Big Indoor Unit Two-piece Style Low Temp. Air to Water Heater Pump welcome to visit our Power World factory in Shenzhen!

    Quality 10.5kw Big Indoor Unit Two-piece Style Low Temperature Air to Water Heater Pump for House & Domestic Water Heating for sale
    Send your message to this supplier
     
    From:
    To: Shenzhen Power World New Energy Technology Co., Ltd.
    Subject:
    Message:
    Characters Remaining: (0/3000)
     
    Find Similar Products By Category:
    Inquiry Cart 0

    Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Contact Us |Help |关于我们 |联系我们

    Copyright © 2009 - 2019 entremaqueros.com. All rights reserved.